Q2) A three phase 400 V, Y- connected synchronous generator has maximum armature current l=420A, synchronous reactance X,-0.25 2. The maximum of excitation voltage EA =308V (phase). The prime mover limit is 290 kW. assume core losses an friction losses amount to 12 kW. 1- Sketch the capability curve of the generator showing Qmax and Pma can be delivered from the generator. 2- Determine the power factor when the stator current and prime-mover power both are with maximum limits. 3- Determine the power factor when the stator current and field current both with maximum limits. 4- Determine the range of lagging power factor operation is possible when the stator current is maximum. "Hint use cosine rule for a triangle"

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q2) A three phase 400 V, Y- connected synchronous generator has maximum armature current lA=420A,
synchronous reactance X,=0.25 Q. The maximum of excitation voltage EA =308V (phase). The prime mover
limit is 290 kW. assume core losses an friction losses amount to 12 kW.
1- Sketch the capability curve of the generator showing Qmax and Pmax can be delivered from the generator.
2- Determine the power factor when the stator current and prime-mover power both are with maximum
limits.
3- Determine the power factor when the stator current and field current both with maximum limits.
4- Determine the range of lagging power factor operation is possible when the stator current is maximum.
"Hint use cosine rule for a triangle"
Transcribed Image Text:Q2) A three phase 400 V, Y- connected synchronous generator has maximum armature current lA=420A, synchronous reactance X,=0.25 Q. The maximum of excitation voltage EA =308V (phase). The prime mover limit is 290 kW. assume core losses an friction losses amount to 12 kW. 1- Sketch the capability curve of the generator showing Qmax and Pmax can be delivered from the generator. 2- Determine the power factor when the stator current and prime-mover power both are with maximum limits. 3- Determine the power factor when the stator current and field current both with maximum limits. 4- Determine the range of lagging power factor operation is possible when the stator current is maximum. "Hint use cosine rule for a triangle"
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,