Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 4, Problem 4.10P
A 60-Hz, three-phase three-wire overhead line has solid cylindrical conductors arranged in the form of an equilateral triangle with 4-ft conductor spacing. The conductor diameter is 0.5 in. Calculate the positive-sequence inductance in Wm and the positive-sequence inductive reactance in
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A Three-phase transposed line is composed of one conductor per phase with flat horizontal spacing of D = 14 meters, as shown in the below figure. The conductors have a diameter of 2.6 cm and
a GMR of 1.012 cm. Find the capacitance per phase per kilometer of the line.
a
C
D
D
2D
Select one:
O a 0.0088 microF/Km
Ob. 0.0077 microF/Km
Oc 1.455 microF/Km
Od. None of these
2.5 A 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontal
spacing with 6.1 m between the centre lines of adjacent phases. The distance between the sub-
conductors of each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find the
inductance per phase per km.
[0.988 mH]
A three phase system with
Dab
Dbc
one conductor per phase
as shown in the figure. The
conductors are stranded
and spaced as shown,
(Dab=Dbc=4m). The
outside diameter of the
phase conductor is 2cm.
The GMR of the phase
conductor is 0.7788 cm.
The value of inductance
per phase is:
Select one:
O a. (1.2445 * 10A-3)
mH/km
O b. (1.1559 * 10^-6)
H/m
O c. (1.4562 * 10A-6) H/m
O d. (1.2945 * 10A-6) H/m
O e. (1.2445 * 10A-6) H/m
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A three phase transposed line has a flat horizontal conductor configuration as shown in the figure. The conductors have a diameter of 3.4 cm and a GMR of 1.35 cm. Find the inductance and capacitance per phase per kilometer of the line. -D =1.2 m -D = 1.2 m · -2D = 2.4 m-arrow_forwardA single phase line has two parallel conductors 2m apart. The diameter of each conductor is 1.2 cm. Calculate the loop inductance/ phase/ kmoftheline.arrow_forwardCalculate the capacitance per km per phase for a 3 phase, 50Hz, double circuit line shown in figure below. Each conductor has a diameter of 25mm and subconductor spacing 0,3m. the line is completely transposed. 0.3m 6 m 6marrow_forward
- 3-phase double circuit line has its conductors at the vertices of a regular hexagon with side3.5 m. The diameter of each conductor is 2 cm. Find the inductance per phase per km.[0.596 mh]arrow_forwardA double-circuit its capacitance to neutral per mile. line is shown below. The conductor radius is 0.0452 ft. Determine 16' 16' a b 22' c' b' a'arrow_forward11. A single 3 phase line operated at 50HZ is arranged as shown in figure. The conductor diameter is 0.6 cm. Find the inductance and capacitance per km. The line is regularly B d2 = 3 m transposed. dz = 2 m d, = 2 marrow_forward
- 3. Find the capacitance per unit length of the single-phase line shown below. Conductors a, b, c are of 0.2 cm radius, and conductors d and e are of 0.4 cm radius. Oa 4m Oe 6ide X Side Yarrow_forwardWhat is the capacitance per kilometer per phase of a single circuit, two bundle conductor line with horizontal configuration? The distance between the bundled conductors is 30 cm and the diameter of each conductor is 5cm. The distance between the centers of the bundle is 5mChoices: 0.0132uF/km 0.0126 uF/km 0.0143uf/km 0.0116uF/km Please in typing format pleasearrow_forwardEach phase of a transmission line is a bundle of 4 conductors that form a square with all sides equal to d=33 cm. Each conductor is stranded and has GMR = 0.5 cm. Find GMR of the bundle to be used in inductance calculations. Express your answer in cm with 2 digits after decimal pointarrow_forward
- Three conductors of a 3-phase overhead line are arranged in a horizontal plane in the order a-b-c, distance between a and b is 6 m, b and c is spaced 6 m apart. The diameter of each line conductor is 2.5 cm. Calculate the Capacitance per phase per km (L1) for this arrangement. Calculate Capacitance per phase per km(L2) if the spacing between the conductors are reduced by half. Calculate the Ratio of C2 with respect to C1. Capacitance in nF per Phase per Km for Arrangement 1 (C1) Capacitance in nF per phase per km for Arrangement 2 (C2) Ratio of C2 to C1arrow_forwardA 5 km long, 3-phase 34.5 kV line has a horizontal configuration of 4 ft. spacing. The conductor is 336.4 ACSR with GMR of 0.0244. What is the inductance of the line? * A. 7.63 mH B. 4.76 mH C. 5.33 mH D. 6.49 mHarrow_forwardA. For the following figure, the diameter of each conductor is 2.5 cm. Find the inductance and capacitance per km per phase. 40 cm 40 cm 40 cm a a' b' 10 m 10 m Phase A Phase B Phase C B. A 3-ph transmission line has 3 conductors b, spaced at the corners of an equilateral triangle of 350 cm side. Each conductor has 1.2 cm diameter. 1. Find the inductance per phase. 2. If the line is constructed with horizontal spacing with suitably transposed conductors, find the spacing between the first and last conductors which would give the same value of inductance as in the equilateral arrangement.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Inductors Explained - The basics how inductors work working principle; Author: The Engineering Mindset;https://www.youtube.com/watch?v=KSylo01n5FY;License: Standard Youtube License