Q.4. Mention the specifications of EIA/TIA recognized cables and its standard number for each type of cable mentioned in the table below. Name of the cabling Specifications (Zo, freq) Standard no: Fiber optic Category3 Category5e Category6
Q: A two conductor main A B, 500 m in length is fed from both ends at 250 volts. Loads of 50 A, 60 A,…
A: Given data, The value of area is A = 1 cm2. The value of resistivity for double conductor is ρL =…
Q: 4. Write all the types of connectors use in optical fiber cable?
A: The connectors mechanically couple and align the cores of fibers so light can pass.
Q: when installing coaxial cable the minimum bending radius generally recommended is
A: Coaxial cable: It is an electrical cable. It consists of an inner conductor along with a concentric…
Q: Define cable rating in a built environment
A: Cable selection and application : It is essential to know cable construction, characteristics,…
Q: Identify and explain the safety procedures and precautions when working with tools and equipment's…
A: Electrical cables are used for transferring the signals and are also used for long distance…
Q: XLPE insulated high voltage underground cable will be installed along a street. The cable will then…
A: Given: XLPE insulated high voltage underground cable will be installed along a street. The cable…
Q: 8- Generally as of the operating voltage which of the following options are the correct words that…
A:
Q: 9. Which type of cable would you use to connect multiple buildings in an industrial facility? A.…
A: Four options are given. We need to choose the correct option. It is asked that which type of cable…
Q: 3. All exposed noncurrent-carrying metal parts of an information technology system shall be to the…
A: All the exposed noncurrent carrying metal parts of an information technology system shall be bonded…
Q: Label the parts of Tubular Steel Poles
A: Steel tabular poles are not commonly used poles these poles are used when there is need of low cost…
Q: 1. Identify and describe the step-by-step process used to pull cable and also describe the…
A: The step-by-step process used to pull cable STEP 1: Check the Cable Width and Pipeline to make sure…
Q: What is RG rating of coaxial cable? Give detailed answer please
A:
Q: n an ungrounded electrical systems with conductors installed in grounded metal raceways and…
A: In an ungrounded electrical system, there is no direct connection with the grounding electrode.…
Q: List the methods by which an equipment grounding conductor is connected to a device box
A:
Q: what is grading of cables, explain proper in details with block diagram
A: In a single-core cable, the conductor is surrounded by the dielectric material with an outer…
Q: Give detailed information about the Fiber optics and Ethernet cables. Compare these two types of…
A:
Q: 6.a. What type of cable installation is typically used in industrial facilities? A. Aerial only B.…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: The Voltage Regulation of a Transmission Line should be _____? A. very high percentage. B. more than…
A: C. Zero or nil Option C is correct.
Q: Define line of support
A: The line support in terms of electrical energy is defined below: - The various kinds of structure…
Q: What type of bonding jumper connects the grounded circuit conductor and the equipment grounding…
A: In a power system , Main bonding jumper connects the grounded circuit conductor and the equipment…
Q: What's the required bend radius for three-conductor, 3/0 AWG service entrance cable that's…
A: Given, Three-conductor, 3/0 AWG service entrance cable that's approximately 1 inch in diameter.
Q: Discuss Suspension insulators are recommended in high voltage transmission lines.
A: Pin encasings become excessively cumbersome an uneconomical past 33 kV. Thus, for voltages higher…
Q: In terminating the coaxial cable, If the present procedure is to loosen up the braided shield and…
A: In terminating the coaxial cable, the the flaring and bending back the outer braid onto the cable…
Q: Which fibre is utilised to protect the inner core and prevent the cable from straining in…
A: The explanation is as follows.
Q: Identify and describe the step-by-step process used to install cable in the any building?
A: Step by step process to install cable in any buildings: step 1: In the slab, a PVC conduit is laid…
Q: Four No. 12 and four No. 10 conductors are to be installed in a EMT conduit. What size EMT conduit…
A: Conductors size is selected on the basis of assigned numbers. As the assigned number increases then…
Q: What is the super tension cable and application,rating
A: In this question we are discussing about super tension cable and application,rating. This is…
Q: What is the type,application and rating of cables?
A: Types of cable are classified according to their Voltage level .
Q: . A grounded circuit conductor and the equipment grounding conductor should always be joined at the…
A: Choose the correct option A grounded circuit conductor and the equipment grounding conductor should…
Q: Write all the types of connectors use in optical fiber cable?
A: The connectors mechanically couple and align the cores of fibers so that light can pass. Connectors…
Q: Identify and describe the step-by-step procedure that is used to draw cable, as well as the…
A: It is asked to describe the step-by-step procedure that is used to draw cable and to install cable…
Q: What is RG rating of coaxial cable? Give detailed answer please
A:
Q: Write all information about cable of extra super voltage?
A:
Q: Which type of cable would you use to connect two buildings in an office installation? A. Buried…
A: Given & to find: Which type of cable would you use to connect two buildings in an office…
Q: Identify and describe the step-by-step process used to pull cable and the step-by-step process used…
A: 1. The first step is to to lay electrical conduction of 2mm thick and 25 mm in size for the PVC…
Q: . What is “accessible” as applied to wiring methods? What is “accessible” as applied to equipment?…
A: In an electrical system, there are various terms which are used for different phenomenon and gives a…
Q: In the conduit diagram shown in attached picture, determine how many wires are in each conduit…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: define the conductor with examples
A: An electrical conductor is defined as substances that permit energy to float via them without…
Q: Explain the meaning of the term “bundle conductor transmission line" and discuss the effects of its…
A: A single-stranded conductor is used for transmitting the power from one end to the other ends when…
Q: 14. If the total circular mil area of the largest ungrounded service-entrance conductor for a…
A: Explanation: The equivalent area of four ungrounded paralleled 500 kcmil conductors is 2000 kcmil.…
Q: 13. If the largest ungrounded service-entrance conductor for a service is 750-kcmil copper, what is…
A: Choose the correct option, If the largest ungrounded service-entrance conductor for a service is…
Q: Identify and describe the step-by-step process used to install cable in the NCT Colledge buildings
A: according to question, Identify and describe the step-by-step process used to install cable in the…
Q: Please explain why it is preferable to use coaxial cable rather than twist pair wire.
A: 1) In real time applications the noise ( unwanted signal) can be add to the required information.…
Q: In terminating the coaxial cable, if the present procedure is to insert the BNC connector, length…
A: Important tools for making a coaxial cable: Compression tool Cable Stripper Compression Connectors…
Q: NEC Article 800.44 states that where communication cables enter buildings, they shall_______. A.…
A: The correct option based on NEC Article 800.44 has been given in the following section:
Q: What size equipment grounding conductor is used with # 8 AWG nonmetallic-sheathed cable
A: The minimum size equipment grounding conductor is selected on the basis of the current rating…
With industry input, the TIA/EIA cable standards have been developed by the Telecommunications Industry Association (TIA) and Electronic Industries Alliance (EIA). TIA/EIA-568-A-1995 defines a standard for building cable system for commercial buildings that support data networks, voice, and video. It also defines the technical and performance criteria for cabling.
Step by step
Solved in 2 steps
- 6. Determine the diameter in inches and in millimeters of circular cables having cross-sectional areas as given below. (Assume the cables to be solid conductors.) a. 250 CM b. 1000 CM c. 250 MCM d. 750 MCM *Round off to 4 decimal digitsA 500MCM ACSR cable has 37 strands. Determine the diameter in mils of each strand.6.a. What type of cable installation is typically used in industrial facilities?A. Aerial onlyB. Buried onlyC. Buried and aerialD. Industrial facilities don't use cable installations.6.b. Which type of fiber is used in a standard FDDI network?A. OM3 or OM4 at 850 nmB. OM1 at 1,550 nmC. OM2 at 1,310 nmD. OM1 at 1,310 nm
- Discuss the technological advancements that have improved bend resistance in modern fiber-optic cables.Write about the uses and importance of twisted pair cable - crossover cable5.a.Which organization determines allowable maximum fill ratios for different cables?A. IEEEB. IECC. ANSID. NEC5.b. When should corner pull boxes be used in an installation?A. At all 90 degree bendsB. At all bends less than 90 degreesC. At all bends greater than 100 degreesD. At all bends
- What is the different b/w solid type cables and pressure cables (oil and gas)... The course is power transmission system and the topic is under ground cables...what is the cladding modes in Optical Fiber delivery system?Which of the following Surge Diverter use non-linear resistances in its fabrication? Rod - Gape SD. Lightning Arrester SD. Expulsion Tube SD. O All of the above.
- where do we find how many #12 THHN conductors can fit in a 1/2 inch EMT conduit?A two conductor street main AB , 500 meters in length is fed from both end at 250 volts. Load of 50A, 60A, 40A and 30A are tat distance of 100m , 250m ,250m, 350m, and 400 m from A ,respectively .If the x-section of the conductors be 1 cm2 and specific resistance of the material of the conductor is 1.7x10-8 Q-m, determine the minimum consumer voltage.Calculate the self-GMD of stranded wire with 2 strands. a. Radius of each strand is 0.001 inch. b. The radius is doubled.c. The radius is halved