Identify and explain the safety procedures and precautions when working with tools and equipment's that should be followed during the installation of the cables?
Q: In terminating the coaxial cable, if the present procedure is to cut part of the braided shield and…
A: In this question we need to find what is the next procedure is to
Q: What NEC chapter contains tables that are used to determine the proper size of a conductor?
A: The NEC is the worldwide accepted code for electrical wiring and installation. To determine the…
Q: Explain the major consideration required for a protective system.
A: In the power plant, the generator is one of the most expensive pieces of equipment; therefore,…
Q: Why is bonding of the conduit necessary when using reducing bushings to properly match a conduit to…
A: In such situations, conduit bonding is done to prevent or mitigate shock hazard as it provides a low…
Q: Why is it important, when soldering connectors onto a piece of electronic circuitry, to leave no…
A: Given: Soldering of connectors
Q: Does the NEC make suggestions about how to wire a house that will be occupied by handicapped…
A: The NEC is the electrical code that is accepted by everyone belongs to the electrical industry. NEC…
Q: Identify and describe the step-by-step process used to pull cable and also describe the step-by-step…
A: According to the question we have to Identify and describe the step-by-step process used to pull…
Q: 2. What fault occurs when Line and Neutral wires come with each other? Which device is actuated?
A: According to the given question, it is required to describe the fault which occurs when a line and a…
Q: Discuss application and uses of earth leakage breaker ?
A: ELCB (Earth Leakage Circuit Breaker):- An ELCB (Earth Leakage Circuit Breaker) is an electrical…
Q: when installing coaxial cable the minimum bending radius generally recommended is
A: Coaxial cable: It is an electrical cable. It consists of an inner conductor along with a concentric…
Q: Q.1: Non-metallic conduit must not be installed where extremes of ambient temperature, why?
A: Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: What type of conduit that should be used where corrosion is a factor?
A:
Q: What device can determine how far a cable damage is?
A: we have to give detail about the device that can determine "how far a cable damage is".
Q: What is the minimum branch circuit wire size that may be installed in a dwelling?
A: Basically, the 14 AWG wiring is used for typical lightening loads in the residence.
Q: Table 314.16(A) of the Code shows the maximum number of conductors permitted in a given size box. In…
A: When setting a job, an electrician often makes a circuit, thinking of the best way to use wires…
Q: 1. Identify and describe the step-by-step process used to pull cable and also describe the…
A: The step-by-step process used to pull cable STEP 1: Check the Cable Width and Pipeline to make sure…
Q: What is the name of the gadget that can determine the distance between a cable's damage and where it…
A: Name of the gadget which is used for finding the cable damage and its location is "Cable Fault…
Q: What kind of instrument is capable of determining the distance to the place of cable damage?
A: The explanation is as follows.
Q: Identify and explain the safety procedures and precautions that should be followed for fire…
A: Procedure that is used to install cable in buildings are as follows:- Electrical conduction for…
Q: 8. What are the common protective links for electrical control lines and what electrical components…
A: Various protective devices or links are used in the electrical control line of the power system.…
Q: How can you calculate the maximum short-circuit current that can pass when the A-B ends of an outlet…
A: The detailed answer is solved below according to the given parameters and instructions in the…
Q: Why is the Insulating plastic of wires color-coded?
A: Wire A wire is a thin, malleable metal strand. The most common way to make wire is to draw the metal…
Q: when the insulation of the equipment tested healthy ? justify .
A: As we know that the current sent through a conductive wire to the destination means to the consumer…
Q: Explain the two main testing process used in testing transmission cables.
A: Fiber optics is a technology that is connected with the transmission of information as light rays…
Q: Identify and describe the step-by-step process used to pull cable and also describe the step-by-step…
A: According to question we have to Identify and describe the step-by-step process used to pull cable…
Q: 45. What section of the Code prohibits the use of sheet metal screws as a means of attaching…
A: As per the bartleby policy you can ask one question at a time so please ask other questions a…
Q: Question#03: Justify: why electrical isolation and theft prevention are the advantages of…
A: 1. The main benefits of non-conductive cable are its isolation from the rest of the system and its…
Q: In terminating the coaxial cable, If the present procedure is to loosen up the braided shield and…
A: In terminating the coaxial cable, the the flaring and bending back the outer braid onto the cable…
Q: Identify and describe the step-by-step process used to install cable in the any building?
A: Step by step process to install cable in any buildings: step 1: In the slab, a PVC conduit is laid…
Q: What is the type,application and rating of cables?
A: Types of cable are classified according to their Voltage level .
Q: 4.Justify: why electrical isolation and theft prevention are the advantages of non-conductive cable?
A: According to the given question, it is required to determine the reason why non-conductive cables…
Q: Identify and describe the step-by-step procedure that is used to draw cable, as well as the…
A: It is asked to describe the step-by-step procedure that is used to draw cable and to install cable…
Q: Identify and describe the step-by-step process used to pull cable and also describe the step-by-step…
A: The step-by-step process used to install cable in buildings are as follows:
Q: In what ways may the Instrusion detection and prevention system be used to reduce the hazards of…
A: Intrusion detection and prevention system is used as no one can enter our system with malicious…
Q: Identify and describe the step-by-step process used to pull cable and the step-by-step process used…
A: 1. The first step is to to lay electrical conduction of 2mm thick and 25 mm in size for the PVC…
Q: Justify: why electrical isolation and theft prevention are the advantages of non-conductive cable?
A: The main advantages of non conductive cable is it's isolation from the rest and most of the…
Q: Airframe Electrical What is the purpose of the inspection hole on a connector contact?
A: There are different kind of connectors. Crimped contacts are mostly used connectors.Connectors are…
Q: What do you mean by permissible current loading of an underground cable?
A: Permissible current loading: It is the maximum amount of current the cable can carry without any…
Q: Airframe Electrical How much of the conductor should be exposed past the end of properly crimped…
A: Crimped contact is used to provide maximum reliability and safety to electrical equipment.There are…
Q: Is it okay to use a cable tray for the horizontal path of telephone lines to their specific outlets?…
A: EMT conduit size (inch) Number of cable 1 4 1-1/4 6 1-1/2 8 2 14 2-1/2 17
Q: Describe the various methods of laying underground cables. What are the relative advantages and…
A: Proper laying and attachment of fittings decide the reliability of underground cables. The fittings…
Q: draw a pictorial/wiring diagram of the jumpers connected to the front panel of a computer system…
A: The Front Panel Connections, also known as the Front Panel Header or FPanel, are a collection of…
Q: Why is it critical to keep cable clutter to a minimum in a rack?
A: It is asked to explain why it is critical to keep cable clutter to a minimum in a rack.
Step by step
Solved in 2 steps
- A cable wire maybe coaxial or twisted. Coaxial costs 25 centavos per meter while twisted wire costs only 18 centavos. The soldering cost for coaxial wire is P1.30 per connection, for twisted wire P1.70. What length of cable run will make the cost of installing coaxial equal to that of the twisted wire. Assume that the number of soldered connection is 350. ANSWER_____________mgive details process of measurement of insualtion resistance of various types of cables. Explain in easy and simple word and detail answera)How do voids in the insulation cause breakdown of the cable? b)How do the various devices protect the penstock?
- F.a-The best method of performing pneumatic system inspection is with a(n)A. ultrasonic listening device.B. vibration listening device.C. screwdriver to your ear.D. careful eye on system operation.F.b- What type of seal system is constructed of a hard brittle material and is often used in a pump to sealbetween the pump and the motor?A. SteelB. FiberglassC. CeramicD. GlassF.c- When a pneumatic solenoid fails, the failure is normally due to aA. weak pilot.B. bad spool.C. ripped seal.D. faulty coil.explain the Reasons for coordinating electrical protectionsLow-voltage conductors. a. are not powerful enough to cause death from electrocution b. must exceed 480V to cause death C. are responsible for most electrocution deaths due to the frequency of contact d. are unlikely to cause injury if rubber-soled shoes are worn
- Training is required for: Qualified electricians only. Only those workers who work on or near exposed energized parts. Both those workers who work on or near exposed energized parts and those who do not. None of the above. a. b. C. d. Workers who are designated as "unqualified:" Do not need any training. Must become "qualified" within one year. a. b. Must not operate electrically powered equipment. Must be trained in safety-related work practices. C. d. Workers who are designated as "qualified." Work on or near exposed energized parts. a. b. Must be trained to distinguish exposed live parts from other parts of electrical equipment. Must be trained to determine the nominal voltage of exposed live parts. C. d. All of the above. Protect yourself from electrical hazards by: Leaving covers off of electrical panels to make inspection a. easier. Wearing specialized personal protective equipment as needed. Pulling fuses instead of locking out during repairs. d. Removing the ground prong from…14 Which type of Insulator is used in Substations to support connections for High Voltage Switchgears, Current Transformers, and etc.? A. SUSPENSION TYPE B. PIN TYPE C. POST TYPE D. STRAIN TYPE2. What fault occurs when Line and Neutral wires come with each other? Which device is actuated?
- Explain the relevance of earthing and bonding in an electrical Installation.5. Why isn't solder permitted to be relied on for grounding electrode connections?A. The solder increases the chances of a ground-fault event occurring.B. The heat from the solder weakens the connection and exposes it to physical damage.C. The use of solder doesn't meet the requirements for corrosive influences.D. The connection's integrity can be negatively affected by heat during a ground-fault event.4. In conceal knob and tubing wiring, the clearance to be maintain between conductors is a. 45 mm b. 76 mm c. 55 mm d. d. 50 mm