Background: In this experiment, the lab instructor created a catecholase enzyme solution using white potatoes. The potato was the source of enzymes and cofactors in the experiment, as potatoes have sufficient amounts of catecholase and, therefore, cofactors for catecholase. A chilled potato had the peel removed by the instructor and then was chopped into pieces. The potato is peeled so that the brown skin does not interfere with the brown color of the benzoquinone. If this were to occur, the absorbance would seem higher due to the brown potato skin in the solution. The potato was chopped so that the blender did not need to work as hard to break open the cells. The instructor then placed the chopped, peeled potato into a chilled blender. The blender is chilled as heat will speed up the rate of reaction. Cold (chilled) distilled water was then added to the potatoes. This was done to break open the cells of the potato. The catecholase and cofactors are inside the potato cells; water is hypotonic and helps break open cells and release more catecholase. Additionally, tap water contains ions that could be additional cofactors and interfere with the experiment's accuracy. For purposes of this experiment, a slowly progressing reaction is desired, as fast reactions are difficult to observe. The potato and distilled water solution were blended in three ten-second bursts, which released the enzyme from the starch matrix of the potato. The potato was blended in intervals to avoid excessive heat that can activate the enzymes and increase the reaction and absorbance rates. The enzyme solution was then strained through cheesecloth to filter out the starch matrix, which can increase the absorbance rate, as starch and cellulose can also absorb light. The blended potato solution was filled into vials until the vials overflowed. This was done because oxygen is a reactant, and overflowing the vials reduced the amount of oxygen in the vials. Five test tubes were obtained. 1 mL of the enzyme was added to each test tube first. Next, 2 mL of EDTA was added to the EDTA test tube. Similarly, 2 mL of PTU was added to the PTU test tube, and 2 mL of citric acid was added to the citric acid test tube. Finally, 2 mL of dH2O was added to the distilled water test tube, and 4 mL of dH2O was added to the blank test tube. 2 mL of catechol was added last because the reaction will start occurring as soon as it is added. Initial measurements of the test tubes were recorded, and each tube was placed back into the test tube rack to sit for ten minutes. This procedure was repeated after ten minutes. During this ten-minute period, the tubes were all inverted every two minutes to keep contents within the solution evenly mixed and prevent starch buildup/settling. The spectrophotometer was calibrated with test tube five again, and measurements for test tubes one through four were re-taken for the second reading. Absorbency readings were recorded in a table, and color change before and after the ten minutes was noted. What is one possible source of error (besides human error) that occurred in this experiment? Explain in detail. How does this error affect the observed and recorded results (absorbance)?

Human Anatomy & Physiology (11th Edition)
11th Edition
ISBN:9780134580999
Author:Elaine N. Marieb, Katja N. Hoehn
Publisher:Elaine N. Marieb, Katja N. Hoehn
Chapter1: The Human Body: An Orientation
Section: Chapter Questions
Problem 1RQ: The correct sequence of levels forming the structural hierarchy is A. (a) organ, organ system,...
icon
Related questions
icon
Concept explainers
Question

Background:

In this experiment, the lab instructor created a catecholase enzyme solution using white potatoes. The potato was the source of enzymes and cofactors in the experiment, as potatoes have sufficient amounts of catecholase and, therefore, cofactors for catecholase. 

A chilled potato had the peel removed by the instructor and then was chopped into pieces. The potato is peeled so that the brown skin does not interfere with the brown color of the benzoquinone. If this were to occur, the absorbance would seem higher due to the brown potato skin in the solution. The potato was chopped so that the blender did not need to work as hard to break open the cells. The instructor then placed the chopped, peeled potato into a chilled blender. The blender is chilled as heat will speed up the rate of reaction. Cold (chilled) distilled water was then added to the potatoes. This was done to break open the cells of the potato. The catecholase and cofactors are inside the potato cells; water is hypotonic and helps break open cells and release more catecholase. Additionally, tap water contains ions that could be additional cofactors and interfere with the experiment's accuracy. For purposes of this experiment, a slowly progressing reaction is desired, as fast reactions are difficult to observe. The potato and distilled water solution were blended in three ten-second bursts, which released the enzyme from the starch matrix of the potato. The potato was blended in intervals to avoid excessive heat that can activate the enzymes and increase the reaction and absorbance rates. The enzyme solution was then strained through cheesecloth to filter out the starch matrix, which can increase the absorbance rate, as starch and cellulose can also absorb light. The blended potato solution was filled into vials until the vials overflowed. This was done because oxygen is a reactant, and overflowing the vials reduced the amount of oxygen in the vials. 

Five test tubes were obtained. 1 mL of the enzyme was added to each test tube first. Next, 2 mL of EDTA was added to the EDTA test tube. Similarly, 2 mL of PTU was added to the PTU test tube, and 2 mL of citric acid was added to the citric acid test tube. Finally, 2 mL of dH2O was added to the distilled water test tube, and 4 mL of dH2O was added to the blank test tube. 2 mL of catechol was added last because the reaction will start occurring as soon as it is added. Initial measurements of the test tubes were recorded, and each tube was placed back into the test tube rack to sit for ten minutes. This procedure was repeated after ten minutes. During this ten-minute period, the tubes were all inverted every two minutes to keep contents within the solution evenly mixed and prevent starch buildup/settling. The spectrophotometer was calibrated with test tube five again, and measurements for test tubes one through four were re-taken for the second reading. Absorbency readings were recorded in a table, and color change before and after the ten minutes was noted. 

What is one possible source of error (besides human error) that occurred in this experiment? Explain in detail. How does this error affect the observed and recorded results (absorbance)? 

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Metabolic pathways
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Human Anatomy & Physiology (11th Edition)
Human Anatomy & Physiology (11th Edition)
Biology
ISBN:
9780134580999
Author:
Elaine N. Marieb, Katja N. Hoehn
Publisher:
PEARSON
Biology 2e
Biology 2e
Biology
ISBN:
9781947172517
Author:
Matthew Douglas, Jung Choi, Mary Ann Clark
Publisher:
OpenStax
Anatomy & Physiology
Anatomy & Physiology
Biology
ISBN:
9781259398629
Author:
McKinley, Michael P., O'loughlin, Valerie Dean, Bidle, Theresa Stouter
Publisher:
Mcgraw Hill Education,
Molecular Biology of the Cell (Sixth Edition)
Molecular Biology of the Cell (Sixth Edition)
Biology
ISBN:
9780815344322
Author:
Bruce Alberts, Alexander D. Johnson, Julian Lewis, David Morgan, Martin Raff, Keith Roberts, Peter Walter
Publisher:
W. W. Norton & Company
Laboratory Manual For Human Anatomy & Physiology
Laboratory Manual For Human Anatomy & Physiology
Biology
ISBN:
9781260159363
Author:
Martin, Terry R., Prentice-craver, Cynthia
Publisher:
McGraw-Hill Publishing Co.
Inquiry Into Life (16th Edition)
Inquiry Into Life (16th Edition)
Biology
ISBN:
9781260231700
Author:
Sylvia S. Mader, Michael Windelspecht
Publisher:
McGraw Hill Education