A 3-ph, 50 Hz, 150 km length O.H.T.L. supplies a load with P MW load at 0.85 lag P.f. and 69 kV where P is the last two digits (from right) of your registration number (i.e for the student that has a registration number 202112396, P = 96.. This T.L has a resistance of 0.232 Q/km and an inductive reactance of 0.783 Q/km and the capacitance to neutral is 0.0446 µF/km. Using nominal circuit, Find: 1- Constants A, B, C, and D. 2- Sending end voltage. 3- Sending end current 4- Voltage regulation of this T.L. 5- Transmission line efficiency. 6- Draw with a scale the phasor diagram of this model at this operating case. 7- Estimate approximately the loadability of this transmission line at this operating voltage. Justify your estimation and suggest a way to increase this loadability. Verify your answer.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.61P
icon
Related questions
Question
1.
A 3-ph, 50 Hz, 150 km length O.H.T.L. supplies a load with P MW load at 0.85 lag P.f. and 69 kV
where P is the last two digits (from right) of your registration number (i.e for the student that has a
registration number 202112396, P = 96). .
This T.L has a resistance of 0.232 Q/km and an inductive reactance of 0.783 Q/km and the
capacitance to neutral is 0.0446 µF/km. Using nominal a circuit, Find:
1- Constants A, B, C, and D.
2- Sending end voltage.
3- Sending end current
4- Voltage regulation of this T.L. 5- Transmission line efficiency.
6- Draw with a scale the phasor diagram of this model at this operating case.
7- Estimate approximately the loadability of this transmission line at this operating voltage. Justify
your estimation and suggest a way to increase this loadability. Verify your answer.
Transcribed Image Text:1. A 3-ph, 50 Hz, 150 km length O.H.T.L. supplies a load with P MW load at 0.85 lag P.f. and 69 kV where P is the last two digits (from right) of your registration number (i.e for the student that has a registration number 202112396, P = 96). . This T.L has a resistance of 0.232 Q/km and an inductive reactance of 0.783 Q/km and the capacitance to neutral is 0.0446 µF/km. Using nominal a circuit, Find: 1- Constants A, B, C, and D. 2- Sending end voltage. 3- Sending end current 4- Voltage regulation of this T.L. 5- Transmission line efficiency. 6- Draw with a scale the phasor diagram of this model at this operating case. 7- Estimate approximately the loadability of this transmission line at this operating voltage. Justify your estimation and suggest a way to increase this loadability. Verify your answer.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Sinusoids and Phasors of Alternating Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning