Determine the dosage and daily consumption of powdered activated carbon (PAC) required for trichloroethylene (TCE) removal given the following design specifications: . Influent concentration = 1 mg/L TCE . Carbon type: Calgon Filtrasorb 400 (12 x 40 mesh); pb = 450 g/L • Freundlich parameters for TCE • Freundlich capacity parameter K = 55.9 (mg/g)(L/mg)¹/n • Freundlich intensity parameter 1/n = 0.48 Treatment objective = 0.005 mg/L TCE Flow rate=378.5 L/min (100 gal/min) . . Assume that no other solutes compete with TCE for adsorption onto the PAC, and that the PAC is saturated at the treatment objective.

Materials Science And Engineering Properties
1st Edition
ISBN:9781111988609
Author:Charles Gilmore
Publisher:Charles Gilmore
Chapter3: The Structure Of Real Materials
Section: Chapter Questions
Problem 3.12P
icon
Related questions
Question
100%
Please upload your full solution to the following problem.
Determine the dosage and daily consumption of powdered activated carbon (PAC) required for
trichloroethylene (TCE) removal given the following design specifications:
6
SUL
Influent concentration = 1 mg/L TCE
Carbon type: Calgon Filtrasorb 400 (12 x 40 mesh); pb = 450 g/L
Freundlich parameters for TCE
• Freundlich capacity parameter K = 55.9 (mg/g)(L/mg)¹/n
• Freundlich intensity parameter 1/n = 0.48
Treatment objective = 0.005 mg/L TCE
Flow rate = 378.5 L/min (100 gal/min)
Assume that no other solutes compete with TCE for adsorption onto the PAC, and that the PAC is
saturated at the treatment objective.
Transcribed Image Text:Please upload your full solution to the following problem. Determine the dosage and daily consumption of powdered activated carbon (PAC) required for trichloroethylene (TCE) removal given the following design specifications: 6 SUL Influent concentration = 1 mg/L TCE Carbon type: Calgon Filtrasorb 400 (12 x 40 mesh); pb = 450 g/L Freundlich parameters for TCE • Freundlich capacity parameter K = 55.9 (mg/g)(L/mg)¹/n • Freundlich intensity parameter 1/n = 0.48 Treatment objective = 0.005 mg/L TCE Flow rate = 378.5 L/min (100 gal/min) Assume that no other solutes compete with TCE for adsorption onto the PAC, and that the PAC is saturated at the treatment objective.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Methods of ground improvement
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Materials Science And Engineering Properties
Materials Science And Engineering Properties
Civil Engineering
ISBN:
9781111988609
Author:
Charles Gilmore
Publisher:
Cengage Learning
Solid Waste Engineering
Solid Waste Engineering
Civil Engineering
ISBN:
9781305635203
Author:
Worrell, William A.
Publisher:
Cengage Learning,