(2) Set the wavelength of the spectrophotometer to 400 nm. . Place the stock solution (Solution 5) in a cuvet following the "blank solution procedure" as above. Measure and record the wavelength and absorbance. Scan the wavelength range of the spectrophotometer while recording absorbance values. You will need to scan manually, setting the absorbance at zero (100% T) with the blank solution (0.1 M HNO3) at EACH chosen wavelength before recording the absorbance of the stock solution. Plot the data, absorbance, A (y-axis) versus the wavelength, à (x-axis), to determine the Amax, the wavelength where maximum absorbance occurs for the cobalt ion. Absorbance 0.6 0.5 0.4 0.3 0.2 0.1 0.0 500% 600 Wavelength (nm) A representative absorption spectrum of a laboratory solution. 148 300 400 700 800

Appl Of Ms Excel In Analytical Chemistry
2nd Edition
ISBN:9781285686691
Author:Crouch
Publisher:Crouch
Chapter4: Least-squares And Calibration Methods
Section: Chapter Questions
Problem 9P
icon
Related questions
Question
zero absorbance or 100 %T. If not, adjust the spectrophotometer
accordingly.
(2) Set the wavelength of the spectrophotometer to 400 nm. . Place the
stock solution (Solution 5) in a cuvet following the "blank solution
procedure" as above. Measure and record the wavelength and
absorbance. Scan the wavelength range of the spectrophotometer
while recording absorbance values. You will need to scan manually,
setting the absorbance at zero (100% T) with the blank solution (0.1
M HNO3) at EACH chosen wavelength before recording the
absorbance of the stock solution.
Plot the data, absorbance, A (y-axis) versus the wavelength, λ (x-axis),
to determine the λmax, the wavelength where maximum absorbance
occurs for the cobalt ion.
Absorbance
0.6
0.5
0.4
0.3
0.2
0.1
0.0
300
400
500.
600
Wavelength (nm)
A representative absorption spectrum of a laboratory solution.
148
Page
.700
(1) Absorbance of the Standard Solutions.
800
4
of 9
O
-
ZOOM +
Transcribed Image Text:zero absorbance or 100 %T. If not, adjust the spectrophotometer accordingly. (2) Set the wavelength of the spectrophotometer to 400 nm. . Place the stock solution (Solution 5) in a cuvet following the "blank solution procedure" as above. Measure and record the wavelength and absorbance. Scan the wavelength range of the spectrophotometer while recording absorbance values. You will need to scan manually, setting the absorbance at zero (100% T) with the blank solution (0.1 M HNO3) at EACH chosen wavelength before recording the absorbance of the stock solution. Plot the data, absorbance, A (y-axis) versus the wavelength, λ (x-axis), to determine the λmax, the wavelength where maximum absorbance occurs for the cobalt ion. Absorbance 0.6 0.5 0.4 0.3 0.2 0.1 0.0 300 400 500. 600 Wavelength (nm) A representative absorption spectrum of a laboratory solution. 148 Page .700 (1) Absorbance of the Standard Solutions. 800 4 of 9 O - ZOOM +
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Spectroanalytical Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning