Positive-sequence components consist of three phasors _________ with magnitudes and _________ phase displacement in positive sequence; negative- sequence components consist of three phasors with ________ magnitudes and _________ phase displacement in negative sequence; and zero-sequence components consist of three phasors with __________ magnitudes and __________ phase displacement.
To fill: The appropriate words in the given blank spaces.
Answer to Problem 8.1MCQ
The appropriate words are: equal,
Explanation of Solution
The method of symmetrical components is used to solve the unbalanced system. This method is also termed as three-component method. The balanced set of components are positive sequence component, negative sequence component and zero-sequence component.
Positive Sequence components: The positive-sequence system is represented by a balanced system of phasors having the same phase sequence (and therefore positive phase rotation) as the original unbalanced system. The phasors of the positive-sequence system are equal in magnitude and displaced from each other by
Negative Sequence components: The negative-sequence system is represented by a balanced system of phasors having the opposite phase sequence (and therefore negative phase rotation) to the original system. The phasors of the negative-sequence system are also equal in magnitude and displaced from each other by
Zero Sequence components: The zero-sequence system is represented by three single phasors that are equal in magnitude and angular displacement between all the phasors is
Therefore, in positive-sequence component, there are three phasors of equal magnitude but
Want to see more full solutions like this?
Chapter 8 Solutions
Power System Analysis and Design (MindTap Course List)
- -The equivalent impedance of a series combination of a 8-ohm resistor, a 8-ohm capacitor, and a 14-ohm inductor has an angle of ____ degrees. -A parallel combination of a 24-ohm resistor and a 32-ohm inductor will result to a total impedance of with horizontal component of ____ ohms. -The equivalent impedance of a series combination of a 8-ohm resistor, a 8-ohm capacitor, and a 14-ohm inductor has a magnitude of ____ ohms.arrow_forward1-In series R-L circuit transients, the momentary current imm is directly proportional to the RMS voltage. Select one: True False 2-Symmetrical components method are used to solve the symmetrical faults. Select one: True False 3-If the circuit has leading power factor, then it is called as _______________ circuit. Inductive Capacitive Resistive Resistive and Inductivearrow_forwardConductor spacings, types, and sizes do have an impact on the series impedance and shunt admittance. True Falsearrow_forward
- A system of three currents equal in magnitude and having zero phase displacement, these are called. Select one: a. negative phase sequence components b. zero phase sequence components c. None of above d. positive phase sequence components.arrow_forward3. Number of sign changes in the entries in 1st column of Routh array denotes the no. of a) Roots of characteristic polynomial in RHP. b) Zeroes of system in RHP. c) Open loop poles d) Open loop zeroes in RHP. in RHP .arrow_forwardDefine and draw unit circle. What is the significance of unit circle for system analysis?arrow_forward
- Schering Bridge is used to find ____________. a. capacitance b. pressure c. inductance d. frequencyarrow_forward4/ Which parameter is neglected or ignored in Short Transmission Lines? A. SHUNT CAPACITANCE ONLY B. SERIES CONDUCTANCE AND SHUNT CAPACITANCE C. SHUNT CONDUCTANCE AND SHUNT CAPACITANCE D. SHUNT CONDUCTANCE ONLYarrow_forwardbus. The reactive power and voltage angle are determined at the end of load flow analysis forarrow_forward
- 400Ω A k=0.9 600Ω B k=0.8 66Ω 600Ωarrow_forwardL-type equivalent circuit and parameters for a continuous sinusoidal phase of a 5.5 kW, 1450 rpm, line voltage 220 V and frequency 50 Hz star-connected 3-phase ASM, ignoring core (iron) losses given as follows: R1=0.21 Ohm, R2=0.18 Ohm, X1=X2=0.66 Ohm and Xm=9.9 Ohm i, i,R, R, jX m १ (1-s) R, S How many times the rated current will the inrush current be when the ASM is started directly? O 4.3763 O 2.6455 O 6.3414 7.1534 O 5.2280 O 8.0815 O 3.7473 O 1.2558arrow_forwardIn the following network, the voltage magnitudes at all buses are equal to 1 p.u., the voltage phase angles are very small, and the line resistances are negligible. All the line reactances are equal to j1 p.u. (1) (2. P₂ = 0.1 p.u. P3 = 0.2 p.u. The voltage phase angle 83 in radian at bus 3 is (Assume one of the generator bus as slack bus and sin-¹ (0.1) = 0.1 rad) (a) -0.1 (b) -0.2 (c) 0.1 (d) 0arrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning