The pump of a water distribution system is powered by a 15-kW electric motor whose efficiency is 90 percent. 300 kPa Pump Water 0 100 kPa 50 L/s "motor = 90% Motor 15 kW 194 Wpump The water flow rate through the pump is 50 L/s. The diame- ters of the inlet and outlet pipes are the same, and the eleva- tion difference across the pump is negligible. If the pressures at the inlet and outlet of the pump are measured to be 100 kPa and 300 kPa (absolute), respectively, determine the mechanical efficiency of the pump.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter40: Typical Operating Conditions
Section: Chapter Questions
Problem 10RQ: The seasonal energy efficiency ratio (SEER) includes the energy used in the _____and _____cycles.
icon
Related questions
Question
100%

THERMODYNAMICS

UPVOTE WILL BE GIVEN. PLEASE WRITE THE COMPLETE SOLUTIONS LEGIBLY. SHOW THE STEP-BY-STEP PROCESS WITH SHORT COMMENT/EXPLANATION. ANSWER IN 4 DECIMAL PLACE

The pump of a water distribution system is powered
by a 15-kW electric motor whose efficiency is 90 percent.
300 kPa
Pump
Water
O
100 kPa
50 L/s
pump
"motor- 90%
Motor
15 kW
The water flow rate through the pump is 50 L/s. The diame-
ters of the inlet and outlet pipes are the same, and the eleva-
tion difference across the pump is negligible. If the pressures
at the inlet and outlet of the pump are measured to be 100
kPa and 300 kPa (absolute), respectively, determine the
mechanical efficiency of the pump.
Transcribed Image Text:The pump of a water distribution system is powered by a 15-kW electric motor whose efficiency is 90 percent. 300 kPa Pump Water O 100 kPa 50 L/s pump "motor- 90% Motor 15 kW The water flow rate through the pump is 50 L/s. The diame- ters of the inlet and outlet pipes are the same, and the eleva- tion difference across the pump is negligible. If the pressures at the inlet and outlet of the pump are measured to be 100 kPa and 300 kPa (absolute), respectively, determine the mechanical efficiency of the pump.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Applied Fluid Mechanics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.