Q5 The single-line diagram of a three-phase power system is shown in Figure Q5a, with equipment ratings given in Table Q5a. (a) (b) G₁ G₂ G3 G4 T₁ T₂ T3 TA Draw the zero, positive and negative-sequence reactance diagrams using 1000 MVA, 765 kV base in the zone of Line 1-2, neglect the (A-Y) transformer phase shifts. Calculate the short circuit current as a result of three-phase bolted fault occurred at bus 1. Line 1-2 Line 1-3 Line 2-3 bus 1 0 Υ ΔΕ Line 1-3 Line 1-2 G₂ Line 2-3 bus 2 Da Figure 05a bus 3 Table Q5a T₂ KEY YE my 1000 MVA, 15 kV, X₁-X₂-0.18 p.u., Xo = 0.07, p.u. 1000 MVA, 15 kV, X₁-X2-0.20 p.u., Xo = 0.10, p.u. 500 MVA, 13.8 kV, X₁-X₂-0.15 p.u., Xo = 0.05, p.u. X₂ = 0.05 p.u. 750 MVA, 13.8 kV, X₁-0.3 p.u., X₂-0.4 p.u., Xo = 0.1, p.u. 1000 MVA, 15 kV (A) / 765 kV (Y), XTI = 0.10 p.u. 1000 MVA, 15 kV (A)/ 765 kV (Y), XT2 = 0.10 p.u. 500MVA, 15 kV (Y) / 765 kV (Y), XT3 = 0.12 p.u. 750 MVA, 15 kV (Y)/765 kV (Y), XT4 = 0.11 p.u. Χ = 50 Ω, Χρ = 150 Ω. X = 40 Ω, X = 100 Ω. Χρ = 40 Ω, Χρ = 100 Ω.
Q5 The single-line diagram of a three-phase power system is shown in Figure Q5a, with equipment ratings given in Table Q5a. (a) (b) G₁ G₂ G3 G4 T₁ T₂ T3 TA Draw the zero, positive and negative-sequence reactance diagrams using 1000 MVA, 765 kV base in the zone of Line 1-2, neglect the (A-Y) transformer phase shifts. Calculate the short circuit current as a result of three-phase bolted fault occurred at bus 1. Line 1-2 Line 1-3 Line 2-3 bus 1 0 Υ ΔΕ Line 1-3 Line 1-2 G₂ Line 2-3 bus 2 Da Figure 05a bus 3 Table Q5a T₂ KEY YE my 1000 MVA, 15 kV, X₁-X₂-0.18 p.u., Xo = 0.07, p.u. 1000 MVA, 15 kV, X₁-X2-0.20 p.u., Xo = 0.10, p.u. 500 MVA, 13.8 kV, X₁-X₂-0.15 p.u., Xo = 0.05, p.u. X₂ = 0.05 p.u. 750 MVA, 13.8 kV, X₁-0.3 p.u., X₂-0.4 p.u., Xo = 0.1, p.u. 1000 MVA, 15 kV (A) / 765 kV (Y), XTI = 0.10 p.u. 1000 MVA, 15 kV (A)/ 765 kV (Y), XT2 = 0.10 p.u. 500MVA, 15 kV (Y) / 765 kV (Y), XT3 = 0.12 p.u. 750 MVA, 15 kV (Y)/765 kV (Y), XT4 = 0.11 p.u. Χ = 50 Ω, Χρ = 150 Ω. X = 40 Ω, X = 100 Ω. Χρ = 40 Ω, Χρ = 100 Ω.
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.53P: The ratings of a three-phase, three-winding transformer are Primary: Y connected, 66kV,15MVA...
Related questions
Concept explainers
Three-Phase Transformers
Three-segment transformers are a type of transformer used to transform voltages of electrical systems into three ranges. Two type transformers are shell-type transformer and core type transformer. In brief, it could be described because of the exquisite kinds of configurations.
Transformer
Ever since electricity has been created, people have started using it in its entirety. We see many types of Transformers in the neighborhoods. Some are smaller in size and some are very large. They are used according to their requirements. Many of us have seen the electrical transformer but they do not know what work they are engaged in.
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 10 steps with 9 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning