Q5 (b) A synchronous generator and a motor are both rated at 30MVA, 2kV and both have transient reactance of 20%. The transmission line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20MW at 0.8 power factor lagging and a terminal voltage of 12.8kV when a symmetrical three-phase fault occurs at the motor terminals. Using the internal voltage of the machines, carry out design calculations to determine: 1. The prefault generator terminal voltage. 2. The sub-transient current in the generator and the motor. 3. The total fault current
Q5 (b) A synchronous generator and a motor are both rated at 30MVA, 2kV and both have transient reactance of 20%. The transmission line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20MW at 0.8 power factor lagging and a terminal voltage of 12.8kV when a symmetrical three-phase fault occurs at the motor terminals. Using the internal voltage of the machines, carry out design calculations to determine: 1. The prefault generator terminal voltage. 2. The sub-transient current in the generator and the motor. 3. The total fault current
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.3MCQ: The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of...
Related questions
Question
- Q5 (b)
- A synchronous generator and a motor are both rated at 30MVA, 2kV and both have transient reactance of 20%. The transmission line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20MW at 0.8 power factor lagging and a terminal voltage of 12.8kV when a symmetrical three-phase fault occurs at the motor terminals. Using the internal voltage of the machines, carry out design calculations to determine:
- 1. The prefault generator terminal voltage.
- 2. The sub-transient current in the generator and the motor.
- 3. The total fault current
- 4. Comment on the relative sizes of the sub-transient currents in the generator and in the motor which were obtained in Q5 (b).
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning