Q2) Draw a graph between air changes per hour and running cost (OMR), based on the following information: • Fan Pressure: 200 Pa • Fan efficiency : 90 % • Cost/KWH: 20 baisa Volume the room: 100 M3 • Air changes per hour: 20, 30,40,50,60
Q: Determine the discharge of a flowing fluid from a nozzle, whose specific gravity is 1.3, the nozzle…
A:
Q: 5. BERNOULLI'S ENERGY EQUATION A garden sprinkler has 80 small holes each 2.5 mm² in area. If water…
A:
Q: In a given setup as defined by the figure below, determine the rate of change in terms of h(t) given…
A:
Q: 04: Design the intake pipes for water treatment plant that serves 200000 capita and the average…
A:
Q: A water line with an internal radius of 6.5 x 10-3 m is connected to a shower head that has 12…
A:
Q: QI: Design a storm water system for the building shown in Figure below, with rainfall intensity of…
A: V(velocity) = 150mm/hr = 0.15m/hr = 4.16667 x 10-5 m/s
Q: When designing forced hot water heating system for a residential building, which of the following…
A: Hi! Thank you for the question, As per the honor code, We’ll answer the first question since the…
Q: Suppose the ambient atmospheric temp profile of an area is given by the following equation: ɼ (°C) =…
A: The variation coeffecient is a statistical indicator of the data points' relative dispersion. Mostly…
Q: Problem 2 :Air flows steadily between two cross sections in a straight pipe of cross-sectional area…
A: The values and figure given in the question are as follows: Pressure at section-1 (P1)=300 kPa…
Q: Air at 100°F and under pressure of 40 psia flows in a 10-in diameter ventilation duct at a mean…
A: Given data:Temperature = 100 oF Pressure at 100 oF = 40 psia Diameter of the pipe = 10 in. = 0.833…
Q: Compare the estimates of TIC {in 2008 dollars) for a thermal oxidizer designed in treat 30,000 scfm…
A: Given data, Total gas flow rate Q = 30,000 scfm Heat recovery efficiency = 50% The f.o.b price (in…
Q: Calculate the AQI and give a description of air that contains 5 ppm CO (8-hour average), 300 pg/m3…
A: AQI : AQI means Air Quality Index which is a measurement of various pollutants that are present in…
Q: F E Water Tower Hydraulics Pump A в Figure 1 Water Supply and Distribution System ¢ ¢ ¢ ¢ ¢
A: Given data: No. of villa's = 15 No. of peoples present in one villa = 20 Total no. of peoples = 15 x…
Q: A 10m dia. Cylindrical tank has a height of 5m and is full of water at 20ºC (unit weight of…
A: Answer-
Q: Calculate the total sound pressure level of multiple sound sources: 55 dB, 68 dB, 25 dB, and 50 dB…
A:
Q: A house is being built. The contractor states that the cost to install electricbaseboard heat will…
A: Solution Given data The cost to install electrical dashboard heat is $2480
Q: Which of the following does not affect the demand for cooling in a given space? Select one:
A: The demand for cooling in a given space directly depends upon the energy consumption.
Q: A classroom that normally contains 40 people is to be air-conditioned with window air-conditioning…
A: Given: The total number of people in the classroom is 40. The cooling capacity of window…
Q: Heat power loss from a district heating line with two separate pipes: How big is the loss in W / m?…
A:
Q: Discuss the systems and equipment available for cooling systems in large buildings.
A: It can be necessary to provide cooling to buildings during warm weather or where there are…
Q: Q2/A/For what velocity of flow of water in a new, clean, 8-in diameter of cast iron pipe would an…
A: Solution: Given: hL = 7.7 m L = 430 m D = 8 in = 0.203 m Ch = 130 (Hazen - Williams coefficient for…
Q: A typical ceiling of a house consists of items shown in the accompanying table. Assume an inside…
A: Given data,
Q: 1. Fire resistant ratings for buildings are seen in units of: a. Degrees Fahrenheit b. Material…
A: Using definition of rating of fire resistant building
Q: 04: Design the intake pipes for water treatment plant that serves 200000 capita and the average…
A: Given data, Population = 200000 Average water consumption =200 L /capita/day Assume velocity =…
Q: Q.13 Figure shows a lawn 40 cm sprinkier with unequal arms. The jets issuing out of the sprinkler…
A:
Q: A swimming pool has 2 pipes A and B to be used for filling. A smaller pipe A working alone can fill…
A: The process of filling the empty space left by an inground pool with gravel, sand, or dirt is known…
Q: P-Green Building features high-efficiency systems the following except: a. Heating b. Lighting c.…
A: In this question we are asked to find out correct option regarding a question from green building…
Q: Calculate dimensions and power requirements for Flocculator to treat 30000 m3/d wastewater flow.…
A: From the mixing basin, the water is taken to a flocculation tank called a flocculator, where it is…
Q: Exam Figure shows à 40 cm sprinkler with unequal arms. The jets issuing out of the sprinkler arm of…
A:
Q: determine the air flow rate , residence time, gravitational separation oval efficiency when the…
A:
Q: For the pipe network shown in the figure below, what is the flow rate in pipe AC? 5.1 cfs QUESTION…
A:
Q: SITUATION: The pipe system shown in figure serves two towns C and D. The highest building in town C…
A: To Determine how many persons can be served in Town C & D.
Q: To drain waste water from a 10-storey building using the single-pipe method, find the diameter of…
A: given-10 storey building2 toilets1 bathtub1 shower2 wash basins2 kitchen sinks
Q: Q3: In venture meter, the volume water through 10 second is 500ml.the total head of water for points…
A: Given :
Q: A special enclosure in a French café was designed to occupy around 30 heavy smokers for any given…
A:
Q: For what velocity of flow of water in a new, clean 6-in schedule 40 steel pipe would an energy loss…
A: Above given data a- we have to compute discharge in first case b- then refigure the velocity and…
Q: Calculate the: size of a roof tank, diameter of pumping main, and power of pump sets, to be fixed…
A: Given Population of flat = 50 persons Water demand = 100 litres/day No. Of Floors = 4 floors
Q: Water flow through a venturi meter an inlet dia. = 100 mm and throat dia. =50 mm , P at inlet = 70…
A:
Q: An office building with three air-conditioning units has an air-conditioningload of 121,000 Btu/hr.…
A: Given:- air-conditioning load of 121,000 Btu/hr. The first unit handles 41,000 Btu/hr, the second…
Q: Problem: 16 Air at 60 °F flows from a large tank through a convergent nozzle, which has an exit…
A:
Q: A forced convection heating system is installed in a house. The lengths of6-inch circular duct that…
A: Given:- circular duct=6 inch kitchen length=6 ft dining room = 12 ft living room =3 ft master…
Q: SITUATION: The pipe system shown in figure serves two towns C and D. The highest building in town C…
A:
Q: Modern urban houses such as a terraced houses are made of high thermal mass structure. Under the hot…
A: Three factors that influence the performance of natural ventilation in terraced houses located in…
Q: 02: Find dimensions (b and h) of wash water channels for one filter, for the follown • Q (discharge…
A: Given data- Wash water channel-Discharge Q for 1 filter=100,000 L/dayfor 2 filters Q=2×100,000…
Q: Q3: Calculate the steady-state CO2 concentration of a single family home with 3 bedrooms, 3 people,…
A: Cin=Cout+GNKQ
Q: Q.71. Write short note on energy efficiency in planning of building.
A: Energy efficiency in planning of building:- A building is said to be good only when it is…
Q: Please include a diagram. Thank you! You have a piping system in your plant that has gotten old and…
A:
Q: D Water Gs=1 1. In a test to determine the discharge coefficient of a 70 by 35 mm Venturi meter, the…
A:
Step by step
Solved in 3 steps with 1 images
- 1. Determine if what type of ventilation to be use (negative or positive pressure) 2. Determine the required air change per hour (ACH) at each room using the fomula ACH = 60(CFM)/VOL CFM = CUBIC FEET PER MINUTE OR FAN CAPACITY VOL = SPACE VOLUME A = FLOOR AREA H = CEILING HEIGHTCalculate the AQI and give a description of air that contains 5 ppm CO (8-hour average), 300 pg/m3 PM-10 {24-hour average), and 0.10 ppm SO2 (24-hour average).An auditorium is 100m in length, 70m in width, and 20m in height. It is ventilated by a system that feeds in fresh air and draws out air at the same rate. Assume that airborne impurities form a well-stirred mixture. The ventilation system is required to reduce air pollutants present at any instant to 5% of their original concentration in 30 min. What inflow (and outflow) rate is required? What fraction of the total auditorium air volume must be vented per minute?
- Problem :3 only (category: friction factor, FE prep): Air at 1 atm and 10°C flows in a 4 cm diameter glass pipe (roughness of 0) at a velocity of 7 m/s. Find the friction factor. Calculate the head loss over a 2 m length of pipe. Air at 1 atm and 10°C has kinematic viscosity of 1.087 x 10-5H.WII Cooling Load Estimation An air conditioned room in the Basra city that measures 3 m wide, 3.5 m high and 6 m deep. The window size 1.5 m*1.5 m, mounted on the wall with no external shading and the door size 2m*1m. Calculate the sensible, latent and total heat gains on the room. What is the required cooling capacity? Assume all specification parameters that must be taken into account when calculating cooling load. 6 m 2 *1 m 3 m 1.5 * 1.5 m NW NE LNL E ESE SSW SSF SW SEThe air coming out of the distillery has 60% relative humidity. How much water will you need to saturate this airstream? After saturation* what will be the temperature and the total volumetric flow rate? Should you also provide soaker hoses in your design? Discuss the reasons why you will or will not include soaker hoses.
- Pls. Answer thank you! A room's sensible space load is from occupants and infiltration, but excluding intentional ventilation, is 3.2 kw. A total of 600 L/s of outside air is required. What is most nearly the room sensible heat ratio?Calculate the overall mass transfer coefficient (1/sec) for an air stripping column removing chloroform (CHCl3) from groundwater. The water flow is 170 gal/min; column diameter = 3.0 ft; the column packing including Rashig rings (25 mm); a liquid diffusivity of 6*10-6 cm2/s; an air-to-water ratio = 100:1. Compare this value to that is the packing were either Berl saddles (25 mm) or Tile (75 mm).Which of the following does not affect the demand for cooling in a given space? Select one: a. Number of occupants in the given space b. Positioning of the room in the house c. Direction where the building is facing d. Cooling capacity of the cooling system
- Calculate the total cooling load for a building at 32° North latitude at time 14 on 21 of August, outdoor design temperature 35 °C, daily range DR = 11.1 deg ⁰C and indoor design temperature 25.5°C. The building has the following data: A-The ceiling is constructed from 152.4 mm lightweight concrete (I.W concrete) and without a suspended ceiling, dark colour (k = 1) and no mechanical ventilation (f = 1) . Area= 25 m². B-South window consists of 3 mm one layer without internal shading, area=4 m², U = 4.5 W/m2 °C. Assume shading coefficient SC = 1 and cooling load temperature difference CLTD=7 °C and cooling load factor CLF=0.55. C- West wall is constructed from 101.6 mm heavyweight concrete wall+finish (H.W. concrete wall+Finish) (group E) and medium colour (k = 0.83) Area= 17.5 m². D-There is another window that has one hinge that causes an infiltration rate of 5 L/(s.m) of infiltrated air. The moving window has a height of 1.5 m and a width of 1 m. E- Four occupants in the…An 80 kph stream of water from a nozzle. How high could the water jet rise without taking into account air resistance?A well-mixed, insulated water storage tank is to be maintained at internal temperature 60°C. The environmental temperature around the tank varies from -25°C to 30°C. The tank's exterior surfaces (total = 125 m²) have four different levels of insulation as indicated in the table. Surface Component Area, Effective RSI, 2 m² 2 m². °C/W Surface A 60.0 Surface B 30.0 Surface C 30.0 Surface D 5.0 Say that just one surface can be selected to have its insulation upgraded such that its effective RSI would be doubled. Which should be selected to achieve the greatest reduction in heat loss? 10.0 15.0 4.0 0.5