iii. A 4- pole 50 Hz turbo generator supplying 50% of its maximum power capability to 0.6 pu load. The operating power (torque) angle 6' is: (a) 6°=45 mech.deg. (b) 8°-15 mech.deg. (c) 8°=30 mech.deg. iv. For a long high voltage transmission line with light loading: (a) The voltage is generally high due to reactive power generated by the line. (b) The voltage is generally high due to the light loading. (c) The voltage is generally high due to high reactive power generated and the low reactive power consumed by the line. v. The ohmic reactance of a 0.1pu, 30KVA, 240/480V single phase transformer referred to the low voltage side is: (a) 0.768 2. (b) 6.25 2. (c) 0.192 2.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
iii. A 4- pole 50 Hz turbo generator supplying 50% of its maximum power capability
to 0.6 pu load. The operating power (torque) angle 6"
(a) 8°-45 mech.deg.
(b) 8-15 mech.deg.
(c) 8°=30 mech.deg.
is:
iv. For a long high voltage transmission line with light loading :
(a) The voltage is generally high due to reactive power generated by the line.
(b) The voltage is generally high due to the light loading.
(c) The voltage is generally high due to high reactive power generated and the low
reactive power consumed by the line.
v. The ohmic reactance of a 0.1pu, 30KVA, 240/480V single phase transformer
referred to the low voltage side is:
(a) 0.768 2.
(b) 6.25 2.
(c) 0.192 2.
Transcribed Image Text:iii. A 4- pole 50 Hz turbo generator supplying 50% of its maximum power capability to 0.6 pu load. The operating power (torque) angle 6" (a) 8°-45 mech.deg. (b) 8-15 mech.deg. (c) 8°=30 mech.deg. is: iv. For a long high voltage transmission line with light loading : (a) The voltage is generally high due to reactive power generated by the line. (b) The voltage is generally high due to the light loading. (c) The voltage is generally high due to high reactive power generated and the low reactive power consumed by the line. v. The ohmic reactance of a 0.1pu, 30KVA, 240/480V single phase transformer referred to the low voltage side is: (a) 0.768 2. (b) 6.25 2. (c) 0.192 2.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,