If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.
Q: 5. What is the minimum depth that a USEB90 cable, used as a service conductor, can be buried…
A: USEB 90 cable is used as underground cable to transfer electrical power in houses. These types of…
Q: 12. What is the primary entity that needs to be consulted with in regards to the location of the…
A: According to the electric code, The meter and the service box should be placed outdoor which can be…
Q: In the conduit layout shown in picture attached, determine how many wires are contained in each…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: what wire size is needed on a one 20 amp, 120-volt laundry branch circuit? what wire size is needed…
A: 12 gauge what wire size is needed on a one 20 amp, 120-volt laundry branch circuit.
Q: Access to and egress from refer to the actual working space requirements about electrical equipment,…
A: Access to and egress from referring to the actual working space requirements about electrical…
Q: The _______ point is where the facilities of the serving utility and the premises wiring connect. A.…
A:
Q: A service disconnection means must be installed adjacent to, within sight of, and no more than…
A: According to question we have to discuss about A service disconnection means must be installed…
Q: A transfer switch shall be required for all fixed or portable optional standby systems for buildings…
A: According to article 702 - Optional Standby System A fixed or portable optional standby systems…
Q: The minimum depth for a 120-volt, 20-ampere, GFCI protected circuit to an outdoor receptacle run…
A: The depth for the underground installation of the cable is described in the Electric code Section…
Q: Explain the diagram
A: The above diagram shows the connection to drive a unipolar stepper motor using ULN2803A Array with a…
Q: homeowner wants to add 12 general-purpose receptacle outlets to the electrical drawings before the…
A: Please refer the attached images for the complete answer..
Q: Which of the following statements about equipment grounding conductors (EGCs) is true? A. The…
A: Statement about the equipment grounding conductors (EGCs)
Q: draw a block diagram of the jumpers connected to the front panel of a computer system unit
A:
Q: ity or enery that are used by
A: The power system consists of electric generation, distribution and customer satisfaction. In a…
Q: If overcurrent protection is not provided at the source of a separately derived system, the…
A: All ordinarily conductive non-current-carrying metal parts and other conductive materials are…
Q: What is the minimum branch circuit wire size that may be installed in a dwelling?
A: Basically, the 14 AWG wiring is used for typical lightening loads in the residence.
Q: 3. All exposed noncurrent-carrying metal parts of an information technology system shall be to the…
A: All the exposed noncurrent carrying metal parts of an information technology system shall be bonded…
Q: When the nameplate of HVAC equipment is marked “Maximum Size Fuse—50 Amperes,” is it permitted to…
A: The device that have the maximum size are generally air conditioner and the refrigerator have the…
Q: when calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load…
A: The dwelling lighting load on the "volt-ampere per ft2" basis is to be calculated for the receptacle…
Q: Which of the following must be notified prior to equipment shutdown for repair? a. Director of…
A: In this question we will write Which must be notified prior to equipment shutdown for repair..
Q: List the methods by which an equipment grounding conductor is connected to a device box
A:
Q: b) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to electrical…
A: Question. b) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to…
Q: What are Diagram,Construction, Operation, Advantages and Disadvantages of Air Circuit Breaker
A:
Q: The required 125v, 1 ohm, 15A or 20A receptacle on rooftos for heating, air-conditioning and…
A: These equations comes under the class of equipment that needs to be serviced or maintenance.…
Q: Identify and describe the step-by-step process used to install cable in the NCT Colledge buildings?…
A: According to the question we need to Identify and Identify and describe the step-by-step process…
Q: mast-type service entrance
A: The service raceway according to NEC is defined as an enclosed channel specially designed to hold…
Q: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
A: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
Q: In selecting the service entrance size, what should be considered?
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: use a conventional 12 volt test light to diagnose components and wires in a computer system . True…
A:
Q: Which room makes use of Split-Circuit receptacles?
A: A lighting layout for a residential floor plan is shown in the question. We need to find out which…
Q: 14. Severe burns, lung damage, eye damage, and hearing loss are all effects of what event? 8 am…
A: In this question we need to choose a correct option
Q: | True
A: Sequence Local that is we pass a value from one sequence to the next
Q: Determine the minimum number of cubic inches required for two 10 AWG conductors passing through a…
A: AWG or American Wire Gauge is the US standard measure for the diameter of electrical conductors. The…
Q: What is the meaning of calculated load?
A: Since many different loads are connected to an electrical supply, it is extremely important to know…
Q: Plans require the installation of surface-mounted fluorescent luminaires on the ceiling of a…
A: As per the NEC surface-mounted fluorescent luminaires that are to be installed on the low-density…
Q: In installing a telephone system in a building, PABX is used up to the riser (conduit is used) and…
A: It is mentioned that in installing a telephone system in a building, PABX is used up to the riser…
Q: S. The general receptacle spacing requirements for all dwelling units are located in Section of the…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: small appliance receptacles included in the 3 volt-ampere per square foot load calculation
A: Small appliances receptacles are those circuits devoted for the utilization of interfacing little…
Q: The NEC is the only code reference used for electrical installations of all types of occupancies…
A:
Q: 18. How many electric meters are provided for this residence?
A: As per the bartleby rule you can ask only one question at a time so please ask other question…
13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.
A. 6
B. 2
C. 4
D. 5
Step by step
Solved in 2 steps
- 6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 1007.A. Ferrous metal raceways or enclosures are made with _______ content.A. steel or brassB. aluminum or ironC. brass or aluminumD. iron or steel7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. SolarRaceway fill calculations are a prerequisite in ____ needed for particular circuits. Select one: A. MATERIAL REQUIREMENTS B. SCHEMATIC REQUIREMENTS C. DETERMINING THE SIZE OF RACEWAY D. CIRCUIT LOADS4.A. If a bonding jumper is installed from a grounded metal box to a grounding-type receptacle, the length ofthe bonding jumper will be betweenA. 2 and 4 feet.B. 2 and 4 inches.C. 6 and 10 feet.D. 6 and 10 inches.4.B. Why isn't solder permitted to be relied on for grounding electrode connections?A. The solder increases the chances of a ground-fault event occurring.B. The heat from the solder weakens the connection and exposes it to physical damage.C. The use of solder doesn't meet the requirements for corrosive influences.D. The connection's integrity can be negatively affected by heat during a ground-fault event.4>c. Which of the following statements about bonding is true?A. The strike terminals of a lightning protection system must be bonded to the building or structure grounding electrode system.B. Bonding requirements on the supply side of the service disconnect are less restrictive.C. Wire-type supply-side bonding jumpers are usually short in length and installed from the…
- 6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steel6. According to the NEC, allowance for the future expansion of installations isA. an exception.B. in everyone's best interest.C. defined.D. a requirement.7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.
- - Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durability11. A 4 AWG copper electrode that's encased in concrete must be a minimum of _______ feet long.A. 20B. 40C. 50D. 30schedules are typically provided to detail the circuits and overcurrent protection required for listribution equipment. Branch-circuit - Outlet C. d. ore distribution points for electrical in .... Switch Panelboard