b) A single-phase induction motor, ¼ hp, 120 V, 50 Hz, 3% slip has the following equivalent circuit parameter. Determine the i) ii) iii) R₁ = 40 X1 = j4.5 Ω Zf = 14 +j15 n Zb= 0.5 +j1.5 Input Current and power factor Input power Develop power
b) A single-phase induction motor, ¼ hp, 120 V, 50 Hz, 3% slip has the following equivalent circuit parameter. Determine the i) ii) iii) R₁ = 40 X1 = j4.5 Ω Zf = 14 +j15 n Zb= 0.5 +j1.5 Input Current and power factor Input power Develop power