An interior column is to be designed as a part of an unbraced frame system, located at ground floor. It is to be pin-supported at the foundation end, and it is to be connected by two W14x68 girders and W18x106 column at the other end. All of the members, including the column described, are made of A36. Architectural specifications require that the column is to be designed as a rolled W-section with depth of 21 inches. The column is expected to carry axial compressive load of 300 kN dead load and 350 kN live load. Length of girders is 4 meters and length of columns is 3.0 meters. Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment of inertia for columns. Use LRFD specifications from 2015 NSCP Vol. 1

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter9: Composite Construction
Section: Chapter Questions
Problem 9.2.1P: A W1422 acts compositely with a 4-inch-thick floor slab whose effective width b is 90 inches. The...
icon
Related questions
Question

An interior column is to be designed as a part of an unbraced frame system, located at ground floor. It is to be pin-supported at the foundation end, and it is to be connected by two W14x68 girders and W18x106 column at the other end. All of the members, including the column described, are made of A36. Architectural specifications require that the column is to be designed as a rolled W-section with depth of 21 inches. The column is expected to carry axial compressive load of 300 kN dead load and 350 kN live load. Length of girders is 4 meters and length of columns is 3.0 meters.

Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment of inertia for columns. Use LRFD specifications from 2015 NSCP Vol. 1.  

Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Compression members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning