A vacuum refrigeration system consists of a large insulated flash chamber kept at low pressure by a steam ejector which pumps vapor to a condenser. condensate is removed by a condensate to an air vent. warm return water enters the flash chamber at 13 c, chilled water comes out of the flash chamber at 5 c. vapor leaving the flash chamber has a quality of 0.97 and the temperature in the condenser is 32 c. for 350 kw of refrigeration.                                                   a) how much chilled water at 5 deg C does this system provide                                                                                   b) how much make up water is needed                                                                                                                        c) how much vapor must the system ejector remove from the flash chamber                                       answers: a) 10.41 kg/s b) 0.1521 kg/s c) 21.7 kg/s

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter50: Commercial, Packaged Rooftop, Variable Refrigerant Flow, And Variable Air Volume Systems
Section: Chapter Questions
Problem 22RQ: Variable refrigerant flow systems sense the ______and _____of the refrigerant to determine the...
icon
Related questions
Question

with schematic diagram 

A vacuum refrigeration system consists of a large insulated flash chamber kept at low pressure by a steam ejector which pumps vapor to a condenser. condensate is removed by a condensate to an air vent. warm return water enters the flash chamber at 13 c, chilled water comes out of the flash chamber at 5 c. vapor leaving the flash chamber has a quality of 0.97 and the temperature in the condenser is 32 c. for 350 kw of refrigeration.                                                   a) how much chilled water at 5 deg C does this system provide                                                                                   b) how much make up water is needed                                                                                                                        c) how much vapor must the system ejector remove from the flash chamber                                       answers: a) 10.41 kg/s b) 0.1521 kg/s c) 21.7 kg/s

 

Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning