A 100/S00 V. 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its internal parameters. The test conditions and derived parameters are as follows Open circut test: The high voltage side terminals were open. The low voltäge side was connected to 10020ª, 50 Hz supply. The low voltage side current was measured as 50245º MA. Short-circuit test The high voltage side terminals were short-circuited. The low voltage side was connected to a variable voltage supply (50 Hz). A full load current of 102-30° A was achieved when the variable voltage supply was at 820° V. The transformer was then put to operation by connecting a load of 400230° 2 to the high voltage side (secondary) while applying a primary voltage of 10020° V. Calculate the primary current (the current drawn from the power supply).

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.10P: A single-phase step-down transformer is rated 13MVA,66kV/11.5kV. With the 11.5 kV winding...
icon
Related questions
Question
A 100/S00 V. 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its
internal parameters. The test conditions and derived parameters are as follows
Open circut test:
The high voltage side terminals were open.
The low voltäge side was connected to 10020ª, 50 Hz supply.
The low voltage side current was measured as 50245º MA.
Short-circuit test
The high voltage side terminals were short-circuited.
The low voltage side was connected to a variable voltage supply (50 Hz).
A full load current of 102-30° A was achieved when the variable voltage supply was at 820° V.
The transformer was then put to operation by connecting a load of 400230° 2 to the high
voltage side (secondary) while applying a primary voltage of 10020º V.
Calculate the primary current (the current drawn from the power supply).
Transcribed Image Text:A 100/S00 V. 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its internal parameters. The test conditions and derived parameters are as follows Open circut test: The high voltage side terminals were open. The low voltäge side was connected to 10020ª, 50 Hz supply. The low voltage side current was measured as 50245º MA. Short-circuit test The high voltage side terminals were short-circuited. The low voltage side was connected to a variable voltage supply (50 Hz). A full load current of 102-30° A was achieved when the variable voltage supply was at 820° V. The transformer was then put to operation by connecting a load of 400230° 2 to the high voltage side (secondary) while applying a primary voltage of 10020º V. Calculate the primary current (the current drawn from the power supply).
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning