3. A 220V, 1-phase submain circuit is used to provide the power supply of a workshop. The estimated full load power consumption of the workshop is 13kW. The submain circuit is wired by single-core PVC copper cables which are enclosed in trunking with 2 other similar circuits at an ambient temperature of 35°C. MCB is used as the protective device for this submain circuit. Determine: (a) the rating of the MCB for the submain circuit; (available MCB ratings for selection: 32 A, 40 A, 50 A, 63A, 100A) (b) the minimum cable size for the submain circuit if allowable voltage drop is limited to 2% of nominal supply voltage and the length of the submain circuit is 63 m.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33MCQ: The direct electrical connection of the windings allows transient over voltages to pass through the...
icon
Related questions
Question
3. A 220V, 1-phase submain circuit is used to provide the power supply of a workshop. The
estimated full load power consumption of the workshop is 13kW. The submain circuit is wired
by single-core PVC copper cables which are enclosed in trunking with 2 other similar circuits at
an ambient temperature of 35°C. MCB is used as the protective device for this submain circuit.
Determine:
(a) the rating of the MCB for the submain circuit;
(available MCB ratings for selection: 32 A, 40 A, 50 A, 63A, 100A)
(b) the minimum cable size for the submain circuit if allowable voltage drop is limited to 2%
of nominal supply voltage and the length of the submain circuit is 63 m.
Transcribed Image Text:3. A 220V, 1-phase submain circuit is used to provide the power supply of a workshop. The estimated full load power consumption of the workshop is 13kW. The submain circuit is wired by single-core PVC copper cables which are enclosed in trunking with 2 other similar circuits at an ambient temperature of 35°C. MCB is used as the protective device for this submain circuit. Determine: (a) the rating of the MCB for the submain circuit; (available MCB ratings for selection: 32 A, 40 A, 50 A, 63A, 100A) (b) the minimum cable size for the submain circuit if allowable voltage drop is limited to 2% of nominal supply voltage and the length of the submain circuit is 63 m.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Solar cell
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning