Given the per unit values below determine the L-L, L-G, L-L-G and 3Phase fault at the location shown in the figure. The
pre-fault voltage at the fault location is 16.5kVL-L. and the load current is negligible. The source impedances shown are the
sub-transient reactances of the generator. Assume 100MVA base.
15kV
100 MVA S
sto
Δ
+ Δ.
15 kV
R 100 MVA
+6
Zines Zune2 = 138
ZLineo=153 2
38
☺ H
Z₁ =j15%
Z₂=112%
Z₁ -17%
15/138 KV
100 MVA
Z₁ = 18%
Z₂ = 17%
Z. =j5%
138/15kV
100 MVA
Z₁ =18%
Z₂ =j7%
Z₁ =j5%
Ⓒ
ZRI=117%
ZR2=112%
ZRO -10%
Z-j0.08 pu
Transcribed Image Text:Given the per unit values below determine the L-L, L-G, L-L-G and 3Phase fault at the location shown in the figure. The pre-fault voltage at the fault location is 16.5kVL-L. and the load current is negligible. The source impedances shown are the sub-transient reactances of the generator. Assume 100MVA base. 15kV 100 MVA S sto Δ + Δ. 15 kV R 100 MVA +6 Zines Zune2 = 138 ZLineo=153 2 38 ☺ H Z₁ =j15% Z₂=112% Z₁ -17% 15/138 KV 100 MVA Z₁ = 18% Z₂ = 17% Z. =j5% 138/15kV 100 MVA Z₁ =18% Z₂ =j7% Z₁ =j5% Ⓒ ZRI=117% ZR2=112% ZRO -10% Z-j0.08 pu
The per unit values of positive, negative and zero sequence reactances of a network at fault are 0-08, 0-07 and 0-05
respectively. Determine the fault current if fault is line-to-line-to-ground.
Transcribed Image Text:The per unit values of positive, negative and zero sequence reactances of a network at fault are 0-08, 0-07 and 0-05 respectively. Determine the fault current if fault is line-to-line-to-ground.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Basic Signals and Its Properties
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning